
In the current industrial landscape, numerous engineers and plant supervisors initially focus on the heat transfer surface area when selecting a heat exchanger. Surface area does play a significant role, yet it represents just one aspect of the overall equation. Indeed, two devices possessing identical areas might exhibit markedly distinct operational results. In practical applications, this variance frequently amounts to 20–40% in total thermal performance. The primary cause behind this phenomenon is straightforward: the configuration of the flow channels.
At Grano, we manufacture reliable gasketed plate heat exchangers (PHE), semi-welded, brazed, and shell-and-tube heat exchangers. Throughout the years, we have assisted countless clients in substituting outdated Alfa Laval, GEA, Tranter, and APV equipment with superior engineered alternatives. These updated models deliver substantially enhanced actual performance without requiring larger dimensions or additional surface area. This discussion will guide you systematically through the reasons why intelligent flow channel configuration stands as the essential element for optimal outcomes.
What Is Flow Channel Structure Really Means
The flow channel essentially refers to the pathway that directs the two fluids to travel within the exchanger in the most productive manner possible.
Échangeurs de chaleur Grano – Alternative à Alfalaval, APV, Tranter et plus (PHE)
· Corrugation angle – Engineers often describe low-angle designs (approximately 30°) as “gentle” plates, which form broad and even channels, whereas high-angle designs (around 60°) qualify as “intense” plates that establish tight and highly disruptive routes.
· Corrugation depth – Greater wave depths promote more vigorous mixing, although they simultaneously elevate pressure resistance.
· Channel spacing – This factor determines the pace at which the fluid travels for a given volume rate.
· Chevron direction and contact points – At the junctions where intense and gentle plates meet, intense localized turbulence emerges prominently.
Grano provides both H-type (high-theta, robust heat transfer) and L-type (low-theta, mild pressure reduction) plates. Such options enable us to tailor the equipment precisely to suit your specific operational needs.
Shell-and-Tube Heat Exchangers
· Baffle spacing and cut size – Standard segmental baffles direct the shell-side fluid perpendicularly across the tubes, while helical baffles or rod baffles minimize vibrations and eliminate inactive regions.
· Tube layout – Arrangements in triangular, square, or rotated-square formations alter the velocity on the shell side.
· Pass arrangement – Configurations such as single-pass, multi-pass, U-tube, or floating-head setups regulate the direction of flow on the tube side.
While Grano primarily concentrates on plate heat exchangers for efficiency improvement tasks, we also produce customized shell-and-tube units whenever the application demands them specifically.
The Most Important Factors That Affect Channel Performance
1. Fluid Velocity
As the fluid gains speed, the slim thermal boundary layer thins further, thereby boosting the heat transfer coefficient substantially. Nevertheless, an optimal range exists. Typically, plate channels perform optimally at speeds ranging from 0.4–1.0 m/s, and tube-side flows prefer 1–2.5 m/s.
2. Pressure Drop
Enhanced heat transfer generally requires increased energy for pumping. An effective design maximizes the Nusselt number while adhering strictly to the permissible pressure drop limits. Grano plates consistently achieve 3–5 times greater heat transfer coefficients compared to conventional shell-and-tube units under equivalent pressure drop conditions.
3. Turbulence Level
Within standard smooth tubes, turbulent conditions commence only beyond Reynolds numbers of approximately 2,000–4,000. Conversely, in corrugated plate channels, robust turbulence initiates at Reynolds numbers as low as 10–100. This characteristic precisely explains why plate heat exchangers readily attain film coefficients of 8,000–12,000 W/m²·K, whereas shell-and-tube units on the shell side seldom exceed 3,000–5,000 W/m²·K.
4. Even Flow Distribution
Should the inlet port feature suboptimal shaping, certain channels might overload with fluid while others barely receive any. Contemporary plate configurations incorporate expansive distribution areas, thereby maintaining flow discrepancies below ±5% throughout each individual channel.
5. Dead Zones and Short-Circuiting
Regions in corners exhibiting minimal velocity or improper baffle intervals foster stagnant zones. These zones diminish the effective heat transfer surface area and accelerate the buildup of deposits. Thoughtful corrugation profiles and precise baffle placements eradicate such issues entirely.
Popular Ways to Improve Flow Channels
Stronger Corrugation Patterns
Grano employs deep-dimple, chocolate-block, and thermal-mix patterns. Clients transitioning from earlier herringbone plates frequently observe 30–50% increased turbulence levels along with considerably improved heat transfer efficiency.
Smarter Baffle Arrangements (Shell-and-Tube)
Implementations of helical baffles or rod-baffle systems can elevate shell-side heat transfer by 25–40%. Simultaneously, they reduce vibrations and slow the rate of fouling compared to traditional segmental baffles.
Inlet Flow Guides
Generous porthole sizes combined with specialized guiding gaskets prevent abrupt jetting. Consequently, they ensure uniform filling of every channel starting from the initial plate.
Multi-Pass and Mixed-Plate Designs
Through strategic placement of H and L plates in sequences like HH-L or H-L-L, or by adopting multi-pass configurations, we accomplish temperature crossover without surpassing pressure-drop boundaries. This capability proves invaluable for applications requiring tight temperature proximity.
Best Channel Strategies for Different Working Conditions
High-Viscosity Fluids
Wide-gap plates or free-flow plates featuring shallow corrugations sustain adequate velocity without generating excessive pressure resistance. Moreover, particles navigate through them with ease.
Services That Foul Easily
Wide-gap plates with channel widths of 8–16 mm significantly reduce the risk of obstruction. Grano’s semi-welded series merges straightforward mechanical cleaning capabilities with the capacity to withstand elevated pressures.
High Temperature and High Pressure
Brazed or fully-welded plate heat exchangers eliminate gaskets altogether. Grano brazed units operate securely up to 450°C and 40 bar. For the identical application, a shell-and-tube counterpart would necessitate a considerably bulkier and weightier structure.
Very Large or Very Small Flow Rates
· For substantial flows, employ single-pass setups paired with gentle L-plates to maintain low pressure drop.
· For minimal flows involving significant temperature shifts, utilize multi-pass arrangements combined with intense H-plates to heighten velocity and the LMTD correction factor.
Final Thought: Smart Flow Channel Design Always Beats Raw Area
A thoughtfully engineered 100 m² plate assembly will invariably outperform a suboptimally designed 130 m² assembly. The superior device provides elevated heat transfer rates, reduced pumping expenses, and extended operational periods between maintenance cleanings.
At Grano, our engineering team commences with your actual process details: the nature of the fluids, their viscosity levels, propensity for fouling, acceptable pressure drop thresholds, and precise temperature profiles. Based on this information, we select or fabricate the ideal corrugation type and pass configuration. The outcome manifests as tangible energy reductions of 20–40% and greater client satisfaction. In addition, our approach ensures that every recommendation aligns with long-term reliability and cost-effectiveness in industrial settings. We prioritize designs that not only meet immediate needs but also adapt to evolving operational demands over time.
Ready to upgrade your old heat exchangers and start saving energy today? Contact Grano now. We will give you a free performance check against your current Alfa Laval, GEA or Tranter units.
FAQ (questions fréquentes)
Q1: Why can two plate heat exchangers with exactly the same area show up to 30% different performance?
A: The vast majority of this variance stems from the corrugation angle and pattern. Intense (high-theta) plates generate considerably stronger turbulence and superior heat transfer coefficients relative to gentle (low-theta) plates. Furthermore, factors like port dimensions, distribution regions, and plate sequencing can contribute an additional 10–20% variation. Understanding these elements allows for more informed selections that enhance overall system efficiency without unnecessary expansions.
Q2: When should I pick wide-gap plates instead of normal ones?
A: Opt for wide-gap or free-flow plates in scenarios where the fluid includes fibers, solids, sludge, or exhibits rapid fouling tendencies (such as in wastewater treatment, food processing, sugar production, biomass handling, and similar processes). The spacious channels permit particles to flow unobstructed, thereby prolonging service intervals between cleanings from mere weeks to several months. This choice not only boosts operational uptime but also lowers maintenance costs significantly in demanding environments.
Q3: Can Grano supply replacement plates that work better than my original OEM plates?
A: Yes, without question. Our replacement plates for Alfa Laval M-series, TL-series, T-series, GEA NT/VT series, Tranter GX/GC series, and comparable models incorporate modern and more effective corrugation patterns than those found in equipment installed 10–20 years prior. The majority of clients experience 15–35% gains in capacity or tighter temperature approaches within the existing frame following a straightforward plate-pack replacement. This upgrade process is seamless, requiring minimal downtime, and delivers immediate improvements in thermal performance and energy utilization across various industrial applications.